Ultrasonic humidifier water tank steaming in formation, nozzle no water mist spray

Author£ºUnknown Source£ºNetwork 2015-05-24 09:42:54

Core tips£ºUltrasonic humidifier water tank steaming in formation, nozzle no water mist spray

 

First check the fan is functioning properly, if there is no wind, you should open the bottom check if the fan is stuck, duct is blocked, the fan is damaged, if the ventilation holes are blown out, you should check the tank water level is too high, causing the control box air duct blockage, the mist nozzle cannot be. At this time, then you can just pour water tank part.


Secondly, one should check the timer is working properly, if damage to the circuit breaker or contact poor contact of the timer, it also can make the fan stops.